MF, MN, and MR Series Pressure Regulators
Tartarini M Series spring-loaded regulators make them ideal for applications requiring sudden changes in capacity or where gas shutoff is solenoid-controlled as with domestic or industrial burners. These regulators can be used with natural, manufactured, propane, other gases, and air so long as they are filtered and do not contain high percentages of benzol.
MF, MN, and MR Series are in conformity with the Pressure Equipment Directive
PED 97/23/EC and are classified in Max. Category IV
|
- Counterbalanced Shutter
- Overpressure and Underpressure
- Shutoff Valve
- Full Seal at Zero Flow
- Ease of Maintenance
- Wide Pressure Regulation Range
- Manual Reset
MN Series (Widened Outlet Flanges) Types MN, MN-AP, MN-APA, and MN-PST: Regulator Types MBN, MBN-AP, MBN-APA, and MBN-PST: Regulator + Shutoff Types MBN-M, MBN-M-AP, MBN-M-APA, and MBN-M-PST: Monitor + Shutoff
MF Series (Same Inlet/Outlet Flanges) Types MF, MF-AP, MF-APA, and MF-PST: Regulator Types MBF, MBF-AP, MBF-APA, and MBF-PST: Regulator + Shutoff Types MBF-M, MBF-M-AP, MBF-M-APA, and MBF-M-PST: Monitor + Shutoff
MR Series (Same Inlet/Outlet Flanges) Types MR, MR-AP, MR-APA, and MR-PST: Regulator Types MBR, MBR-AP, MBR-APA, and MBAR-PST: Regulator + Shutoff Types MBR-M, MBR-M-AP, MBR-M-APA, and MBR-M-PST: Monitor + Shutoff
All MN, MF, and MR type regulators or regulators + shutoff, are available with or without: Type SR: Silencer
MN Series: DN 25 x 65, 40 x 80, 50 x 100, 65 x 100, 80 x 150, and 100 x 200 / NPS 1 x 2-1/2, 1-1/2 x 3, 2 x 4, 2-1/2 x 4, 3 x 6, and 4 x 8 MF Series: DN 25, 40, 50, 80, and 100 / NPS 1, 1-1/2, 2, 3, and 4 MR Series: DN 50 / NPS 2
MN and MF Series: Body Allowable Pressure: Up to 20 bar / 290 psig Actuator Allowable Pressure: 4 bar / 58 psig Maximum Operating Pressure: 3 bar / 43.5 psig Permissible Inlet Pressure: Standard Version DN 25 to 50 / NPS 1 to 2: 10 bar / 145 psig Standard Version DN 65 to 100 / NPS 2-1/2 to 4: 5 bar / 72.5 psig PST, AP and APA Versions: 19.6 bar / 284 psig
MR Series: Body Allowable Pressure: Up to 12 bar / Up to 174 psig Actuator Allowable Pressure: Up to 12 bar / Up to 174 psig Maximum Operating Pressure: 3 bar / 43.5 psig Permissible Inlet Pressure: Standard Version: 10 bar / 145 psig PST, AP and APA Versions: 12 bar / 174 psig
Standard Version: 10 to 500 mbar / 0.15 to 7.25 psig PST Version: 0.25 to 0.5 bar / 3.63 to 7.25 psig AP Version: 0.5 to 1 bar / 7.25 to 14.5 psig APA Version: 1 to 3 bar / 14.5 to 43.5 psig
Up to ±5%
Up to 10%
Independent pneumatic control Accuracy class: ±5% Response time: <1 second
Standard Version Working: -10° to 60°C / 14° to 140°F Low Temperature Version Available on Request