Approvals & Certificates | Product Certificates & Approvals | Certificate & Approval: Rex ATEX Baseefa (Ex) | English | Certificate & Approval: Rex DIBt, WHG (TÜV overfill protection), Germany | English | Certificate & Approval: Rex FOUNDATION™ fieldbus registration certificate | English | Certificate & Approval: Rex IECEx (Ex) | English | Certificate & Approval: Rex UL & ULC (Ex) | English | Rex (Rosemount 3900) EC Declaration of Conformity (CE mark) | English | Product & Service Documentation | Brochures | Brochure: Emulation: Hook up New Performance to Your Old System | English | Brochure: Every Drop Counts | English | Brochure: Hydrostatic to Hybrid Tank Gauging, TankRadar Rex | English | Brochure: LNG TankRadar | English | Brochure: SIL 2: The Safety Reputation is Confirmed | English | Brochure: Tank Intelligence | English | Brochure: TankRadar Rex, All Radar Gauges are not TankRadar | English | Smart Wireless Tank Gauging from Emerson | English | Data Sheets - Bulletins - Catalogs | Data Sheet: Emulation, Enraf | English | Data Sheet: Emulation, GPE | English | Data Sheet: Emulation, L&J | English | Data Sheet: Emulation, Sakura | English | Data Sheet: Emulation, Varec | English | Data Sheet: Emulation, Whessoe | English | Data Sheet: Reliable Leakage Detection | English | Data Sheet: Rosemount Tank Gauging System with FOUNDATION™ fieldbus | English | Data Sheet: RTG 3900 L Series (TankRadar Rex) | English | Data Sheet: RTG 3960, LNG Gauge (TankRadar Rex) | English | Data Sheet: RTG 3960, LPG Gauge (TankRadar Rex) | English | Data Sheet: Smart Wireless THUM Adapter for TankRadar Rex and Pro | English | Data Sheet: Tank Gauging System Overview | English | Data Sheet: TRL Upgrade to TankRadar Rex | English | Product Catalog: TankRadar Rex Technical Description | English | Spare Parts Catalog | English | Drawings & Schematics | Drawing: El. Inst. Dwg. JB 140-11 Exe | English | Drawing: El. Inst. Dwg. JB 140-15 Exi | English | Drawing: El. Inst. Dwg. JB 36/42, Temp connection box (intrinsically safe cables) | English | Drawing: El. Inst. Dwg. PC-FBM 2180-JB/RTG | English | Drawing: El. Inst. Dwg. RDU 40-Rex | English | Drawing: El. Inst. Dwg. Rex Power - FF bus (Non-IS) conn. (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, Analog Output connection RTG (W1/X11) | English | Drawing: El. Inst. Dwg. Rex, IOT5110 | English | Drawing: El. Inst. Dwg. Rex, IOT5120 | English | Drawing: El. Inst. Dwg. Rex, IOT5130 | English | Drawing: El. Inst. Dwg. Rex, IOT5140 | English | Drawing: El. Inst. Dwg. Rex, IOT51XX K2-ADE RS232-RS485 modem | English | Drawing: El. Inst. Dwg. Rex, IOT51XX Westermo MA-45 RS232-RS485 modem | English | Drawing: El. Inst. Dwg. Rex, Power - RS 485 connection RTG (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, Power-TRL/2 Bus Connection RTG (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, Power-TRL/2 Enraf Bus Connection RTG (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, Profibus DP connection RTG (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, RDU/SDAU and analog input RTG (W12/X12) | English | Drawing: El. Inst. Dwg. Rex, RDU/SDAU, Analog Input and FF-bus (W12/X12) | English | Drawing: El. Inst. Dwg. Rex, Relay 1 connection RTG (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, Relay 1+2 connection RTG (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, RS 485 connection sec bus RTG (W11/X11)r | English | Drawing: El. Inst. Dwg. Rex, SA-3AS modem FCU - TankMaster PC | English | Drawing: El. Inst. Dwg. Rex, Sakura / TIC connection (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, Tankway L&J connection RTG (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, Temp sensor connection RTG (W12/X12) | English | Drawing: El. Inst. Dwg. Rex, Tiway Adapter connection RTG (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, Varec Mark/Space connection RTG (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, Whessoe/GPE connection RTG (W11/X11) | English | Drawing: El. Inst. Dwg. Rex, WLS+ temp connection RTG (W12/X12) | English | Drawing: Mech. Inst. Dwg. Rex, Installation instruction Reflector Kit LPG still-pipe | English | Drawing: Mech. Inst. Dwg. Rex, LPG/LNG Gauge, RTG 3960 | English | Drawing: Mech. Inst. Dwg. Rex, Ref. pin to still-pipe | English | Drawing: Mech. Inst. Dwg. Rex, Reflector Kit LPG Still-pipe (Alt. A) | English | Drawing: Mech. Inst. Dwg. Rex, Reflector Kit LPG Still-pipe (Alt. B) | English | Drawing: Mech. Inst. Dwg. Rex, Requirements on Still-pipe and its installation (RTG 3960) | English | Drawing: Mech. Inst. Dwg. RTG 3960, 2-in. connection | English | Manuals & Guides | Manaul: TankRadar Rex Special Safety Instruction ATEX | English | Manual: Rex SIL 2 Safety Manual | English | Manual: Rex with FOUNDATION™ fieldbus Reference Manual | English | Manual: TankRadar Rex Commissioning Manual | English | Manual: TankRadar Rex Installation Manual | English | Manual: TankRadar Rex Service Manual | English | Manual: TankRadar Rex Special Safety Instruction | English | Wireless Tank Gauging (Rex and Pro) Reference Manual | English | Proven Results | Proven Result: Overfill Protection for Increased Safety | English | Technical White Papers | Technical Note: Extended waveguide for small nozzles | English | Software Downloads | Device Drivers | Software Downloads: Profibus GSD files for TankRadar Rex and Pro | English | Software Downloads: Rex 1.I4 and 1.I5 ini files | English |
- Highest accuracy for inventory and custody transfer on tanks with liquiefied gas
- Antenna installed in 100 mm (4 in.) still-pipe, ensuring a strong echo even under surface boiling and turbulent conditions
- TÜV-tested and approved for overfill protection according to WHG regulations
- Suitable for SIL 2 applications in accordance with IEC 61508/61511
See also TankRadar Rex Technical Description. Instrument accuracy: RTG 3900: ± 0.5 mm (± 0.020 in.). RTG 3900 L: ± 3 mm (± 0.12 in.). Ambient operating temperature: -40 to +70 °C (-40 to +158 °F). Hazardous locations certifications: II 1/2 G EEx d[ia] IIB T6 (Tamb -40 to +70 °C) according to ATEX directive EN 50014, EN 50018, EN 50020, EN 50284 (Europe), and Class 1, Div 1, Groups C and D according to UL 1203, UL 913 and UL 508 (USA). IECEx d IIB T6 (Tamb -40 to +60 °C). Ingress protection: IP 66 & 67. Housing material: Anodized aluminium. Power supply: 100-240 VAC, 34-70 VAC (option), 20-28 VDC (option), 48-99 VDC (option). Analog outputs: One output, 4-20 mA passive or active (non-intrinsically safe) Analog inputs: alt 1) One or two 4-20 mA alt 2) One 4-20 mA input plus one digital HART input (the RTG is HART master. Each RTG can have maximum 3 HART slaves). Relay outputs: Max 2 relays, only one output available if analog outputs are included. Field bus (standard): TRL/2 Bus or RS485.
Field bus (options):
- Profibus DP.
- Tiway (only one relay available, analog output not available).
- Foundation™ fieldbus (non-IS: only one relay available, analog output not available. IS: only one analog input available).
Other vendors’ communication protocols:
- Enraf (requires special Field Bus Modem, EBM).
- Varec (only one relay available, analog output not available).
- L&J (only one relay available, analog output not available)
- Whessoe (only one relay available, analog output not available)
- GPE (only one relay available, analog output not available)
- Sakura (only one relay available, analog output not available)
- Tokyo Keiso (only one relay available, analog output not available)
Temperature inputs: Up to 6 temperature inputs (PT 100) with common return or 3 with individual wiring directly into the gauge. Up to 14 temperature inputs to each gauge via separate Data Acqusition Unit (DAU). Temperature conversion accuracy: ± 0.1 °C for -50 to +250 °C (-58 to +482 °F). Note! Temperature range for PTB approval is -20 to +90 °C (-4 to +194 °F). Total weight for transmitter head without flange: 12 kg (26 lbs). Field data display: In separate DAU or RDU. Antennas: All antennas are of drip-off type in accordance with API (Ch. 3.1 B, Ed 1). For antenna specific data, see below.
See also TankRadar Rex Technical Description. Instrument accuracy: RTG 3960: ± 0.5 mm (0.020 in.) RTG 3960 L: ± 3 mm (0.12 in.) Operating temperature at ball valve: -55 to 90 °C (-67 to 194 °F). Operating temperature in tank: -170 to 90 °C (-274 to 194 °F). Measuring range: 0.5 to 60 m (1.6 to 200 ft) from cone end. For longer measuring range, please consult your Rosemount Tank Gauging representative. Maximum pressure: Up to 25 bar (365 psig). Note! Flanges may have higher pressure rating than 25 bar, but maximum tank pressure is 25 bar. Pressure rating: PN 10 bar/150 psi. PN 20 bar/300 psi. PN 40 bar/600 psi. Pressure sensor: Druck PTX 621. Flange: 6-in. Still-pipe dimension: 4-in. (Sch. 10 or Sch 40). 100 mm (99 mm inner diameter). Total weight: 6-in. 150 psi flange:appr. 38 kg (84 lbs). 6-in. 300 psi flange: appr. 48 kg (106 lbs). 6-in. 600 psi flange: appr. 68 kg (150 lbs). Material exposed to tank atmosphere: Antenna: Acid proof steel (type 316) and quartz. Sealing: Quartz. Ball valve sealing kit (option): 20 or 60 bar (290 or 870 psi), the higher pressure for 600 psi flange only. |
|
|