Model MCL Monochloramine Measuring System
- COMPLETE SYSTEM INCLUDES sensor, connecting cable, analyzer, and flow controller.
- NO REAGENTS NEEDED
- VARIOPOL QUICK-DISCONNECT FITTINGS make replacing sensor easy.
- AVAILABLE WITH CHOICE OF TWO FEATURE-PACKED ANALYZERS.
|
The Model MCL is a complete system for the determination of monochloramine in fresh water. It consists of an analyzer (choice of Model 54eA or Model 1056), a 499ACL-03 sensor, and a constant head flow controller. The analyzer and flow controller are mounted on a back plate, and a quick disconnect Variopol sensor cable is pre-wired to the analyzer, making installation and startup fast and easy. SAMPLE REQUIREMENTS Pressure: 3 to 65 psig (122 to 549 kPa abs) Inlet check valve opens at 3 psig (122 kPa abs). If the check valve is removed, minimum pressure is 1 psig (108 kpa abs). Temperature: 32 to 122°F (0 to 50°) Flow: 3-80 gal/hr (11-303 L/hr) Sample Conductivity: >10 μS/cm at 25°C Process connection: ¼" OD tubing compression fitting (can be removed and replaced with barbed fitting for soft tubing). Drain connection: ¾" barbed fitting. Sample must drain to open atmosphere. Wetted parts: acrylic, nylon, polycarbonate, polyester, Kynar, silicone, Noryl, Viton, silicone, and Zitex, PTFE, (Gold mesh cathode - not normally wetted) Response time to step change in monochloramine concentration: <60 sec to 95% of final reading for inlet sample flow of 17 gph (64 L/hr). Weight/shipping weight: 10 lb/13 lb (4.5 kg/6.0 kg)
SPECIFICATIONS — SENSOR Range: 0 to 6 ppm as Cl2. For higher ranges, consult the factory. pH range: Signal is practically independent of pH between pH 7.0 and 10.0. Sensor current at pH 10.0 is within 5% of sensor current at pH 7.0. Accuracy: Accuracy depends on the accuracy of the chemical test used to calibrate the sensor. Linearity: 2% (typ.) Electrolyte volume: 25 mL (approx.) Electrolyte life: 2 months (approx.)
SPECIFICATIONS — 1056 ANALYZER Case: Polycarbonate NEMA 4X/CSA 4 (IP65). Display: Monochromatic back-lit LCD. Main character height 0.6 in (15mm). Display is user-programable Languages: English, German, Italian, Spanish, French, Portuguese Ambient temperature and humidity: 32 to 131°F (0 to 55°C); RH 5 to 95% (con-condensing) Storage temperature: -4 to 140°F (-20°C and 60°C) Power: 85 to 265 Vac, 47.5-65.0 Hz 15 W Equipment protected throughout by double insulation. RFI/EMI: EN-61326 LVD: EN-61010-1 Outputs: Two 4-20 mA or 0-20 mA isolated outputs. Continuously adjustable. Linear or logarithmic. Maximum load 550 ohms. Output dampening with time constant of 5 sec is userselectable. Ordinary Location (option -68 only): POLLUTION DEGREE 2: Normally only non-conductive pollution occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected. Maximum Relay Current Resistive Inductive 28 Vdc 5.0A 3.0A 115 Vac 5.0A 3.0A 230 Vac 5.0A 1.5A |
|
|