Rosemount Thermocouples English or US-Style (183)
Rosemount English style Thermocouples come a variety of industry standard types, offering the optimum solution for any temperature measurement.
Every US style Thermocouple is part of our global network ensuring a globally consistent, high quality product every time.
|
|
- |
Fully potted and sealed wiring connections |
|
- |
High performance sensor element technology for accurate, vibration-resistant operation |
|
- |
Accredited, global calibration facilities with traceability to international standards |
|
- |
Manufacturing capacity for your largest and most complex projects |
|
- |
Complete assembly of thermocouple, thermowell, extension, and transmitter |
|
- |
Wake frequency calculations |
|
ISA Themocouple Types |
Thermocouple Wire Alloys |
Temperature Ranges |
Limits of Error (Interchangeability) |
|
°C |
°F |
|
J |
Iron/ Constantan |
0 to 760 |
32 to 1400 |
±1.1 °C or ±0.4% of measured temperature, whichever is greater |
|
K |
Chrome/Alumel |
0 to 1150 |
32 to 2102 |
±1.1 °C or ±0.4% of measured temperature, whichever is greater |
|
E |
Chromel/Constantan |
0 to 871 |
32 to 1600 |
±1.0 °C or ±0.4% of measured temperature, whichever is greater |
|
T |
Copper/Constantan |
-180 to 0
|
-292 to 32
|
±1.0 °C or ±1.5% of measured temperature, whichever is greater |
| 0 to 371 |
32 to 700 |