Rosemount 3095 MultiVariable™ Transmitter
The Rosemount 3095 MultiVariable accurately measures differential pressure, static pressure, and process temperature to dynamically calculate fully compensated mass flow. While traditional meters measure a single process variable, the Rosemount 3095 MultiVariable simultaneously measures all process variables necessary for calculating flow.
The Rosemount 3095 can also be pre-assembled and configured to a number of primary elements to provide a full line of flowmeters:
- 3095MFA Annubar® Flowmeters
- 3095MFC Compact Orifice Flowmeters
- 3095MFP Integral Orifice Flowmeters
Learn More
|
|
3095 Family |
 |
- Ten year stability under actual process conditions
- Unprecedented reliability backed by a limited 12-year warranty
- Coplanar™ platform enables DP Flowmeters
- 1.0% Mass Flow rate accuracy over 10:1 Flow Range
- Industry leading performance with ±0.05% of DP reading accuracy
- Four outputs from one device including "Real-Time" fully-compensated Mass Flow and advanced data and event logging
|
| |
3095MA |
3095MV |
3095FT |
3095FB |
3095FC |
| Output |
4-20 HART |
FOUNDATION fieldbus |
HART |
MODBUS |
MODBUS |
| Variables |
DP, GP/AP, Temp, Mass Flow |
DP, GP/AP, Temp, Mass Flow |
DP, GP/AP, Temp, Mass Flow |
DP, GP/AP, Temp |
DP, GP/AP, Temp, Mass Flow, Energy |
| Fluids Database |
All Fluids & Mixtures |
All Fluids & Mixtures |
AGA Natural Gas |
|
Natural Gas, Steam & Water |
Primary Element Database |
Flowmeter Offering, All Primaries |
Flowmeter Offering, All Primaries |
AGA / ISO Orifice |
|
AGA Orifice, 485 Annubar |
| Data Logging |
|
Historian |
API21.1 35+ Days |
|
API21.1 35+ Days |
| Software |
EA 5.5.1 HART |
EA 5.5.1 Fieldbus |
3095FT UI |
3095FB UI |
3095FC UI |
| Complete Specifications: 3095MA, 3095MV, 3095FT, 3095FB, 3095FC |
|
 |
| Better Measurement. Real Results. |
| • |
Scalable measurement to best fit individual applications |
| • |
Patented Saturn™ sensing technology delivers the highest level of performance |
| • |
Industry’s first %-of-reading specification delivering 10x performance improvement |
| • |
Easy installation with industry standard RTD cable |
| • |
Sensor matching using Callendar-Van Dusen constants for high performance temperature measurement | | |
| |
|
 |
 |
 |
| Annubar® Flowmeter Series |
Compact Orifice Flowmeter Series |
Integral Orifice Flowmeter Series |
| • |
Realize energy savings through minimal permanent pressure loss |
| • |
Reduce installation cost for large line sizes with a single pipe penetration | |
| • |
Reduce installed cost compared to a traditional orifice plate |
| • |
Minimize straight-run requirement with conditioning technology | |
| • |
Improved accuracy in small lines |
| • |
Self-centering orifice plate |
| • |
Precision honed pipe section | | |
| |
|
| |
Simplified Installation and Configuration |
 |
| |
| • |
Full configuration in 5 screens, 5 minutes | |
| |
| • |
Windows-based navigation | |
| |
| • |
"Test-Calc" function allows instant verification of flow calculation | |
| |
Reduced Maintenance and Calibration Time |
| |
| • |
Status screen aid in troubleshooting | |
| |
| • |
Calibration with graphical interface for verification and full trim | | |
| |
|
| • Convert a digital HART signal into three additional analog signals |
| • Obtain valuable information from multivariable devices |
| • Easy to configure and install |
| • Accessory product for multivariable instruments |
| • Available as either High-alarm or Low-alarm device |
 | |
|
|