E-Series Advanced Diagnostics  

Improve plant performance

Rosemount E-Series Advanced Diagnostics provide more instrument and process information than any other magnetic flowmeter on the market. This information then enables better decision making and plant management.

This suite of Diagnostics enables you to improve your practices by providing you with a comprehensive package of instrument and process information. The Advanced Diagnostic process information will help to reduce commissioning time, improve process control, and improve the long term reliability of your flow measurements. Advanced Diagnostic instrument information reduces maintenance costs by providing troubleshooting capabilities that are easily accessible with a HART communicator or AMS® Suite: Intelligent Device Manager.

  • The ground and wiring fault detection diagnostic allows you to quickly verify that your installation is correct.
  • E-Series high process noise detection diagnoses the cause of a noisy flow measurement and provides a means to remove the variability.
  • With the Emerson meter verification diagnostic you can confirm the health of the entire flowmeter – transmitter and sensor – without any external equipment. In addition, it’s no longer necessary to remove the sensor from the process line, which saves time and money. 
 
 
 
DocumentationFeatures & BenefitsSpecificationsApplicationsAvailability
 Product & Service Documentation
 Brochures
 Brochure: Rosemount E-Series Magnetic Flowmeters
7 MBpdfMay 2008AA
English
 Brohure: Meter Verification and Diagnostics for the Complete Flow Loop (Emerson Overview)
2 KBhtm
English
 Data Sheets - Bulletins - Catalogs
 Configuration Data Sheet: Rosemount 8700 Series
379 KBpdfMarch 2009UA
English
 Data Sheet: Rosemount 8700 Series Magnetic Flowmeter Systems
4 MBpdfApril 2009TA
English
 Manuals & Guides
 Manual: Rosemount 8712 Remote Mount Magnetic Flowmeter System
7 MBpdfJuly 2009AA
English
 Manual: Rosemount 8732 Integral Mount or Remote Mount Magnetic Flowmeter System
10 MBpdfMarch 2008BA
English
 Manual: Rosemount 8732 Integral Mount or Remote Mount Magnetic Flowmeter System with FOUNDATION™ fieldbus
5 MBpdfOctober 2008AA
English
 Technical White Papers
 White Paper: 8714i Calibration Verification
286 KBpdfJanuary 2008A
English
 White Paper: Ground and Wiring Fault Detection
91 KBpdfJanuary 2008A
English
 White Paper: Tunable Empty Pipe
42 KBpdfApril 2007A
English
 White Paper: Understanding the High Process Noise Diagnostic
328 KBpdfJanuary 2008A
English
 Training & Demos
 Demonstrations
 High Process Noise Detection in Action Video
2 KBhtm
English
Quick Links 
Emerson Exchange