MVS205 Multi-Variable Sensor
The MVS205 Multi-Variable Sensor provides static pressure, differential pressure, and process temperature inputs to a ROC300-Series, ROC800-Series, FloBoss™ 107, FloBoss 407, or FloBoss 500-Series Flow Managers. The inputs from an MVS sensor are used for differential pressure type calculations. The MVS205 typically operates as a remote unit that communicates via a serial format.
ROC300-Series controllers require a Remote MVS Interface (CMA8H). FloBoss 500-Series units require a remote MVS Interface (CR1).
|
|
|
Two versions of the MVS transmitter are available:
- MVS205P with reference accuracy of 0.075% of the full span.
- MVS205E with reference accuracy of 0.10% of the full span.
Evaluated per the Following Standards: CSA C22.2 No. 30. CSA C22.2 No. 213. UL 1203, UL 1604.
Product Markings for Hazardous Locations: Class I, Division 1, Groups C and D. Class I, Division 2, Groups A, B, C, and D, T5 (Tamb=70°C [158°F]), T4 (Tamb=75°C [167°F]). Type 4X.
Approved by Measurement Canada for use with approved flow computers. Approved as MVS205R Series Remote Sensors (Measurement Canada approval #AG-0412). See product data, or specification sheets, for full details. These are available in the documentation tab on this page. |
|
|