Type OSE: Slam-Shut Valve DN 25 to DN 150 with Internal Bypass / NPS 1 to 6
Type OSE LS: Slam-Shut Valve DN 200 and DN 250 with External Bypass / NPS 8 and 10 Manually Operated
North America
WCC Steel
1 and 2-inch NPT
NPS 1, 2, 3, 4, 6, 8 and 10 / DN 25, 50, 80, 100, 150, 200 and 250
CL150, CL300 or CL600
Cast Iron
1 and 2-inch NPT
NPS 1, 2, 3, 4, and 6 NPS / DN 25, 50, 80, 100, and 150
CL125, CL250
Europe, Middle East, and Africa
DN 25, 50, 80, 100, 150, 200, and 250 / NPS 1, 2, 3, 4, 6, 8, and 10
North America
Maximum Inlet Pressure: 1470 psig / 101 bar
Maximum Set Pressure: 1470 psig / 101 bar or max. body rating
Minimum Set Pressure: 4.02-inches w.c. / 10 mbar
Maximum Shutoff Pressure Differential 1470 psig / 101 bar or max. body rating
Europe, Middle East, and Africa
Maximum Inlet Pressure: 100 bar / 1450 psig
Maximum Set Pressure: 101 bar / 1470 psig or max. body rating
Minimum Set Pressure: 10 mbar / 4.02-inches w.c.
Maximum Shutoff Pressure Differnetial 100 bar / 1450 psig
Spring Ranges: 10 mbar to 72,9 bar / 4.02-inches w.c. to 1058 psig
Maximum Sensing Inlet Pressure: 72,9 bar / 1058 psig
Setpoint Tolerance: 0,004 bar / 0.058 psig to 12,0 bar / 174 psig
Maximum Difference Between Overpressure and Underpressure:
33,0 bar / 479 psig
External
North America
-20° to 150°F / -29° to 66°C
Europe, Middle East, and Africa
-30° to 80°C / -22° to 176°F
1/4 NPT
1/4 NPT
Ÿ Explosion-proof switch
Ÿ Non-explosion-proof limit switch
Ÿ Solenoid
Ÿ Additional manometric device for extra pressure sensing
16 to 577 kg / 36 to 1272 lbs depending on the body size and end connection style
For additional technical information, contact your local Sales Office or refer to technical documentation.