LP-GAS REFERENCE 
LP-Gas Reference 

The LP-Gas Reference section includes articles covering technical talks, safety practices, troubleshooting, inspection, cold weather effects, and other topics relating to regulators, valves, and LP-Gas accessories. If there is something you need to know about a product or topic that is not covered, please contact the local LP-Gas Distributor in your area.

Introduction

Regulator Installation
Flooded Equipment
Two-Stage Regulation
Troubleshooting Truck Pumping Systems
Safety Practices for Domestic Tank Fittings
How Cold Weather Affects Tank Capacity
Keeping Fisher Internal Valves Working
Inspecting LP-Gas Regulators
Complying with NFPA 58 Transfer Area and Bulk Plant Liquid Opening Requirements
Give a Regulator the Attention it Deserves 
How Drip Lips Can Prevent Regulator Freeze-Ups
Facts About Freezing Regulators
Transfer Area Valving
______________________________________________________________________

REFERENCE DESCRIPTION

 REGULATOR INSTALLATION:  Shows proper vent position when making new installations or updating old ones. Discusses both safety improvements and longer service life effects of installation with vents positioned correctly.

 FLOODED EQUIPMENT:  Potential hazards of regulators, tank and cylinder valves, propane gas lines, and bulk plant equipment completely submerged by floodwaters.

 TWO-STAGE REGULATION:  Advantages of two-stage regulator systems such as giving more uniform regulation, better relief protection, and reduced trouble calls.

 TROUBLESHOOTING TRUCK PUMPING SYSTEMS:  Discusses problems, possible causes, and potential solutions to bobtail or transport pumping system that doesn't work.

 SAFETY PRACTICES FOR DOMESTIC TANK FITTINGS BULLETIN (LP-26):  Periodic maintenance and inspection requirements of several domestic tank fittings such as filler valves, relief valves, liquid withdrawal valves, and service valves.

 HOW COLD WEATHER AFFECTS TANK CAPACITY BULLETIN (LP-27):  Covers the tank and its vaporization rate during winter conditions. Also discusses temperature differential which is an important consideration in the vaporization equation.

 KEEPING FISHER INTERNAL VALVES WORKING BULLETIN (LP-19):  A thorough discussion about the operation, installation, maintenance, and troubleshooting procedures for Fisher internal valves.

 INSPECTING LP-GAS REGULATORS: WHAT TO LOOK FOR BULLETIN (LP-32):  Service life of a regulator, how to reduce chance of vent blockage, and ways to inspect for internal corrosion.

 COMPLYING WITH NFPA 58 TRANSFER AREA AND BULK PLANT LIQUID OPENING REQUIREMENTS BULLETIN (LP-29):  How valves and accessories can be used to satisfy NFPA 58 requirements regarding the transfer area at LP-Gas bulk plants.

 GIVE A REGULATOR ATTENTION IT DESERVES BULLETIN (LP-15):  How domestic self-operated regulators work and gives installation and maintenance tips.

 HOW DRIP LIPS CAN PREVENT REGULATOR FREEZE-UPS BULLETIN (LP-18):  Shows how drip-lip style vents can reduce the possibility of vent blockage due to freezing rain or sleet.

 FACTS ABOUT FREEZING REGULATORS BULLETIN (LP-24):  How a regulator can freeze internally and tells how to minimize freeze-up problems.

 TRANSFER AREA VALVING BULLETIN (LP-37):  Introduces and shows features of different transfer area valving such as emergency shutoff valves (ESV), back check valves, and internal valves for bulk plant and tank car applications.