Daniel CRA Liquid Turbine Meter
Daniel CRA (commercial-rated) Turbine Meter is ideal for applications in which an economical meter is appropriate.
Daniel has engineered and built this instrument for high-pressure systems, and for both corrosive and non-corrosive liquids. It is available in diameters from 3/4 inch to 2 inches.
Customers rely on Daniel CRA Turbine Meter for use on waterflood secondary recovery, fuel metering systems, LPG, petroleum products and crude oil. This meter is available with either male NPT or ANSI-flanged connections.
|
- Engineered and built for small-line flow applications
- Well-suited for high-pressure applications
- Tungsten carbide shaft for higher reliability and longer meter life
Temperature ranges
- Meter temperature range: -50oF to + 450oF
- Coil temperature range: -50oF to + 225oF
For maximum temperatures up to +350oF, use coil 504-05-398 and connector 504-05-447. For maximum temperatures up to +450oF, use coil 5054-05-397 with special “CRA” Housing. No connector required. Note: At temperatures above 150oF, the pre-amp must be remote mounted.
Industrial grade
- Linearity: ± 1% of flow rate
- Repeatability: ± 0.05%
Instrumentation grade
- Linearity: ± 0.5% of flow rate
- Repeatability: ± 0.05%
Materials of construction
- Flanges: Carbon Steel
- Body: 316 Stainless Steel
- Integral hangers/bearings: Ryton
- Shaft: Tungsten Carbide
- Rotor: 25.5 PH Stainless Steel
- Thrust balls: Tungsten Carbide
- Hanger retainer: 302 Stainless Steel
- Coil adaptor: 304 Stainless Steel
- Waterflood secondary recovery
- Non-custody measurement of petroleum products
|
|
|